IBM 000-974 Braindumps
| Exam details |
|---|
| 000-974 : Power Systems Technical Support for i |
| Certification provider: IBM |
Get IBM 000-974 exam training tips straight from the front lines with 000-974 exam dumps. With 100% free dump access to literally thousands of brain dumps and special 000-974 exam braindumps.
You get quality 000-974 exam information from reliable IT community members who have already passed their 000-974 exam and are using IBM technologies on a daily basis. Use their free brain dumps to advance your own career and then help those who come behind you by creating a new 000-974 questions and answers sample tests with what you find most valuable as a successful and passing IBM 000-974 exam student.
Join the free braindump and 000-974 exam braindump community by contributing to existing 000-974 brain dumps by suggesting explanations, possible solutions and answers, and of course by submitting your own content to be used by others. Who knows, your 000-974 exam dump could make it into one of our 000-974 Master Dumps!
| 000-974 Braindumps | |||||
|---|---|---|---|---|---|
Title |
File |
Rating |
Date |
||
![]() |
000-974 IBM exam | 10.00 | Oct 29,09 | ||
| 974 took an exam in early October and Scored in The high forty percent after an intense weekend of studying. got this study material and scored more then 61%in late October. this Material is now presented to you through this channel. it has also been provided to other testing material locations that sell this information as well (see cap letters for name(s)). Enjoy, and if i am wrong post the corrections - brain dumps are what each of us makes of it. 1.) A corporation is running a Model 810 with a V5R2 OS and plans to upgrade to V6R1. Which of the following is a supported upgrade path? A.) V5R2 to V6R1 using the skipped release method B.) V5R2 to V6R1 using the IBM director Upgrade Manager C.) V5R2 to V6R1 using the Automatic Installation process D.) V5R2 to V5R4M5 followed by V5R4M5 to V6R1 using the Two-Step Upgrade process Answer: D, Multiple Upgrades are required if upgrading from anything priot to V5R3. In this case two upgrades would be required. 2.) What is the minimum V6R1 SCSI Load Source disk size? A.) 17 GB B.) 35 GB C.) 70 GB D.) 140 GB Answer: A, Load source unit must be 17GB or greater and ensure that enough reserved space is allocated for LIC. The Key is SCSI. IF it was a SAS drive the minimum requirement is 70 GB. 3.) What is a unique advantage of using VMWare ESX on an iSCSI attached Server? A.) VMWare ESX can host Windows or Linux Images B.) System I Data and VMWare images can be consolidated into a single backup C.) VMWare allows multiple virtual servers to run on a single hardware server D.) VMWare increases I/O performance of applications by using virtual Ethernet Answer: B, Process of elimination helps you arrive here - answers A and C are the purposes of VMWare in any environment but B is the unique advantage of VMWare ESX in an i Environment. D is a function of the hardware and will not be speed up through the use of VMWare ESX. 4.) Using Software Encryption with Backup Recovery Media Services (BRMS) provides the ability to encrypt user data to which of the following devices? A.) IASP B.) Optical C.) Virtual Optical D.) Tape or Virtual Tape Answer: D, BRMS provides Software encryption for Any Tape Device, Tape Library or Virtual Tape. Introduce in V6R1 5. A Customer is upgrading from a model 520 running V5R2 TO V6R1. Which of the following is the recommended upgrade method? A.) Skipped Release B.) Two-Step Release c.) Manual Installation D.) Automatic Installation Answer: B, Multiple Upgrades are required if upgrading from anything priot to V5R3. In this case two upgrades would be required. 6.) Which of the following allows remote access to an IBM i console running on an HMC? A.) Telnet (Port 23) to the IP address of the HMC B.) Telnet (Port 2300) to the IP address of the HMC C.) HTTP (Port 80) to the IP address of the version 7 HMC D.) Telnet (Port 2001) to the IP address of the partition Answer: A, Telnet is provided by IP Port 23 so this eliminates B and D. HTTP is used for publishing to the Internet and is not designed for two way communications for Command type activities so C is out. A is the answer 7.) Which of the following options will provide the fastest inter partition network communiction A.) Assign a virtual ethernet adapter in each partition and connect them to the same VLAN. B.) Place an FC #5706 dual port ethernet adapter in each partition and connect them via a dedicated switch. C.) Place a FC#5700 fibre Ethernet adapter in one partition, cable it to the on board fibre Thernet port, then map it to the second partition. D.) On a FC #5706 dual port Ethernet adapter, allocate the first port to the first partition and allocate the second port to the second partition, then connect the two ports with a cross over cable. Anser: A, The purpose of virtualization is to allow multiple systems to share hardware. In this case they are sharing ethernet communications equipment but virtual LAN is faster. B,C and D require hardware as part of the solution and hardware will always be slower virtual. 8.) A power6 520 Customer is implementing a new application. The application requires continuous network connectivity. Which of the following solutions will enable fault tolerant connection? A.) Add a second LAN card and team them together using Virtual IP and Proxy ARP. B.) Add a second LAN card and use Network Dispatcher to manage failover functions. C.) Create a virtual LAN with multiple interfaces in the event of port failure. D.) Use both ports on the embedded LAN to set up virtual IP Interfacesand bind them together. Answer: A, Redundancy is built upon hardware. Tw o pieces of hardware that repeat the function if the other piece fails. C and D require virtual which is a single point of failure. In A the IP addrss is virual but that is only so the application can send messages to the IP address. If one card fails the other card still acceppts communication for the IP address. 9.) Which of the following tape drives supports hardware encryption? A.) SCSI-attached TS3200 with LTO3 B.) SCSI-attached TS3100 with LTO4 C.) Fibre-attached TS3200 with LTO3 D.) Fibre-attached TS3100 with LTO4 Answer: D, Per IBM only the TS3100 can support hardware encryption and it must be a Fibre attached drive. IT can support either an LTO3 or LTO4 drive so that is just added for confusion. For further information please see ftp://ftp.software.ibm.com/common/ssi/pm/sp/n/tsd02024usen/TSD02024USEN.PDF 10.) Which of the following is the maximum number of 3.5 inch disk drives allowable in the system unit of a power 520? A.) 6 B.) 8 C.) 10 D.) 12 Answer: A, Six is the maximum 3.5 inch disk drives that can be included in the CEC of a 520 system, regardless if it as an M15 or M25. Anything higher would have to go in a drawer. Eight, though tempting is the answer for the Power 5 systems and thus incorrect here. 11.) Which of the following provides performance data from an IBM i partition which can later be analyzed? A.) iDoctor B.) Service Agent C.) PAtrol Predict D.) Workload Estimator Answer: A, Call the Doctor for this kind of work. For additional information see https://www-912.ibm.com/i_dir/iDoctor.nsf 12.) Using uncapped processors in a partition allows which of the following? A.) A partition to utilize processor cycles from other partitions B.) A micro partition to use up one full processor more then was allocated C.) An IBM i partition to use processors dedicated to AIX or Windows partitions D.) The partitions to use processor cycles from another partition provided it is not powered on. Answer: A, Uncapped processors can take advantage of available processing units within the processor pool - that is the point of them being uncapped. 13.) Which of the following hardware and IBM icombinations can use the shared processor pool groups to help limit required software licenses? A.) Power 6 with V5R4 B.) Power 5 with V6R1 C.) Power 5+ with V5R4 D.) Power 5+ with V6R1 Answer: A, This is not a function of the OS but of the hardware. On a Power 5 system you can't use the Shared Proccesor Pool to reduce the required software licenses, but on Power 6 you can. Since Power 6 is required only A can be correct. 14.) What color are the connectors for HSL-1, HSL-2 and 12X? A.) HSL-1 Black, HSL-2 orange, 12X Green B.) HSL-1 yellow, HSL-2 Black, 12X Green C.) HSL-1 Yellow, HSL-2 Orange, 12X Green D.) HSL-1 orange, HSL-2 Black, 12X Yellow Answer: B, HSL 2 is black and there is no orange so that leaves B. (My trick is to use the 2 to remind me second letter in alapabet is B for black, and O in orange is zero which equals naught.) 15.) When implementing a new Power server with V6R1, the SPT shows that the number of I licenses is less then the total number of proccessors assigned to each partition. Why is this possible? A.) Licensing is based on the "Desired" number of processors B.) A license is not required for the first partition on a Power 6 Server C.) When calculating the number of licenses the SPT disregards partial processors D.) The "Processor pool groups" capability can reduce the number of licenses required Answer: D, This is not a function of the OS but of the hardware. On a Power 5 system you can't use the Shared Proccesor Pool to reduce the required software licenses, but on Power 6 you can use "Processor Pool Groups" to achieve this result. 16. Which of the followng commands are used to generate virtual disk and attach it to a hosted partition? A.) CRTVRTDSK, LNKVRTDSK B.) CRTNWSSTG, ADDNWSSTGL c.) CRTDSKVRT, ADDVRTDSKL D.) CRTVRTSTG, CRTVRTDSKL Answer: A, Now this a tougher one. The fact is that CRTVRTDSK command seems to be correct as the others do not exist. The problem that I have is the "LNKVRTDSK" command is not found and I believe this is a syntax issue. THe command, most likely, should be ADDLNKVRTDSK. Close to C but a search for CRTDSKVRT indicates no matches across the entire Internet. The only command of the eight I can find in the attached document is CRTVRTDSK. Search it if you would like http://www.omniuser.org/Downloads/System%20i%20Navigator%20Tasks%20on%20the%20Web.pdf It is a PDF copy of an IBM website I found. Anyway, go with A. 17.) Which Intrusion Detection Policy can monitor for an unusually high rate of TCP/IP Connections? A.) Perpetual Echo Policy B.) Detection Scan Policy c.) Traffic Regulation Policy D.) Restricte IP Options Policy Answer: C, This example traffic regulation policy traces suspicious traffic across the network, such as an unusually high rate of TCP connections from website: http://publib.boulder.ibm.com/infocenter/iseries/v6r1m0/index.jsp?topic=/rzaub/rzaubexampletraffic1.htm 18.) Historical Performance data can be imported into the Workload Estimator tool from which of the following sources? A.) IBM director B.) Performance Data c.) System i Navigator D.) PM for Power Systems Answer: C, Once agagin - which one do you choose. B or D is wrong from the top. A - IBM director oversees all of the hardware It doesn't focus on the OS. Workload Estimator is an iBM solution and in i5OS it would have been System Direcotor Navigator for I5OS. But that is not an answer available so the answer has to be C. 19. Starting in IBM iV5R4 only one TCP/IP Port must be open from an IBM iPartition to the Internet for Electronic Customer Support and Service Agent to reach IBM. Which of the following ports is the single required port? A.) 80 B.) 443 c.) 500 D.) 4500 Answer: A, 80 must be open but a secure connection can be established after connection is made. Support for HTTP, HTTPs, and HTTP proxy in addition to the previous VPN support to enable more networking flexibility when communicating with IBM electronic customer support centers. From... http://www-01.ibm.com/cgi-bin/common/ssi/ssialias?infotype=an&subtype=ca&htmlfid=897/ENUS206-015&appname=isource&language=enus 20.) A Customer wants to implement an unattended back-up solution that includes incremental and full system saves. Which of the following satisfies the Customer's requirements? A.) Tivoli Storage Manager (TSM) and IBM director scheduler B.) Virtual Storage Manager (VSM) and Advanced Job Scheduler for IBM I c.) Media and Storage Extensions (MSE) and System i Navigator with Job Scheduling D.) Back-up and Recovery media Services (BRMS) and Advanced Job Scheduler for IBM I Answer: D, take it backwards- first unattended is exactly what Advanced Job Scheduler for I does and This is not a virtual solution - it's back-up as in BRMS 21.) A Customer has a Power550 with two partitions. There is a high volume of network traffic between the two partitions. Which of the following is the least expensive way to move the traffic off the customer's existing network infrastructure? A.) Install a FC#5706 Ethernet card in each partition and install a cros over cable between the two cards B.) Install a new high performance Ethernet switch to move the traffic off the existing network infrastructure c.) Define Virtual Ethernet adapters in each partition and establish a virtual LAN connection between the two partitions. D.) Allocate one port on the four port IVE to each partition and install a new Ethernt switch to connect the ports on the IVE card. Answer: C, The purpose of virtualization is to allow multiple systems to share hardware. In this case they are sharing ethernet communications equipment but virtual LAN is faster. A, B, and D require hardware as part of the solution and IBM hardware is expensive. 22.) When creating a hosted IBM i partition, what must be specified in the type parameter of the CRTNWSD command? A.) *HOST, *OPSYS B.) *GUEST, *OPSYS c.) *ISCSI, *OPSYS D.) *IXSVR, *OPSYS Answer: B. *GUEST: Create a network server description for a guest operating system running in a logical partition. For further information please look at the following web site - none of the other parameters exist with CRTNWSD... http://publib.boulder.ibm.com/iseries/v5r1/ic2924/index.htm?info/cl/crtnwsd.htm 23.) Which of the following allows two concurrent disk failures in an array with reduced recovery time? A.) RAID 5 B.) RAID 6 c.) RAID 5 with Hot SPARE 6.) RAID 6 with HOT SPARE Answer: B, RAID 6 is about concurrent drive failures. It is like RAID 5 with hot spare but the spare is already incorporated in the array to prevent concurrent disk failure. That is what the question asked. 24.) Which is the minimum number of PCI adapter slots required for a new, non partioned Power 570 which requires 4 ethernet lines with seperate network address paths to the network? A.) 0 B.) 1 C.) 2 D.) 3 Answer: A, If you are buying this new you would include an order for FC 5639, a four port ethernet card that uses a Serial Port. No PCI slot required so the answer is zero. 25.) A Customer has a model 800 running V5R3. They have some internal fixed function terminal users, some client server applications and provide web access for their external Customers. A migration to a new model M25 Express with IBM i Licensing is planned Which of the following will estimate the number of entitlements needed on the new system? A.) Run the RTVORDNF command B.) Run the IBM DSPESTUSR tool on the model 800 c.) Display details on WRKLICINF for 5722-SS1 FC#5050 on the model 800 D.) Use DSPUSRPRF *ALL to an outfile, then run a query to count all enabled user profiles Answer: C, The WRKLICINF command lists out all the licenses in the system See website for details... http://publib.boulder.ibm.com/iseries/v5r1/ic2924/index.htm?info/cl/wrklicin.htm Not sure about the rest of the noise but the commands listed in A, B and D don't have anything to do with this so go with C. 26.) Which of the following is the highest level of mirroring that can be achieved using a JS12 blade in a BladeCenter S (BCS) with internal BCS drives? A.) Bus level mirroring B.) Disk Level Mirroring c.) Tower-Level Mirroring D.) Controller LEvel Mirroring Answer: B, The JS12 is not as configurable as other solutions. There is only one Disk Controller running out of a single Bus with a maximum of two disks. The System can support RAID-0 or RAID-1 but this is achieved at the disk level therefore B. If you want to know more about this configuration go to.... http://www-03.ibm.com/systems/bladecenter/hardware/servers/js12/specs.html 27.) Which of the following is IBM's preferred PTF delivery method? A.) HMC service Agent B.) Electronic Downlaod c.) Ship media to Customer D.) IBM director Download Manager Answer: B, Though D might sound interesting it isn't a feature -just look on the web. IBM is pushing for ECS through the Internet and this includes downloading PTFs. If they said Intenet download you would immediately guess that so the confused us with "Electronic Downlaod" Check out the following... http://www.ibm.com/products/finder/us/finders?pg=ddfinder&cm_re=other-_-suprcn-_-download/ Awfully fancy if it wasn't the preferred way to get PTFs, it is. 28.) Electronic Service Agent is a no-charge tool that performs which of the following tasks? A.) Performs dynamic processor and memory tuning? B.) Performs scheduled software maintenance including APARS and PTFs c.) Gathers and reports inventory using the inventory Scout feature included with the IVM D.) Proactively monitors and reports hardware events, such as system errors, performance issues and inventory Answer: D, ESA is all about the hardware. See the following website for additional information... http://publib.boulder.ibm.com/infocenter/iseries/v5r4/index.jsp?topic=/rzaji/service_agent.htm 29.) What is the minimum requirement for configuring and running the System i for Web on IBM I 6.1? A.) Integrated Web Server B.) WebSphere Portal Express c.) Integrated Server Support D.) Websphere Application Server Express Answer: D, Because IBM says it is this one and the other three are not listed in the requirements document, please see... http://publib.boulder.ibm.com/infocenter/iseries/v6r1m0/index.jsp?topic=/rzamm/rzammsoftwarerequirements.htm 30.) What type of remote journaling should be configured in an environment which experiences occassional communication failures? A.) Standby B.) Synchronous c.) Asynchronous D.) Burst with autosync Answer: C. Asynchronous is the way to go because this allows the transaction to be complete on the production machine before it submits it to the second machine. IBM doesn't explain this well but this Internet site does... http://searchdatabackup.techtarget.com/generic/0,295582,sid187_gci1300168,00.html# 31.) Which of the following blade Expansion feature card formts is used for Ethernet and Fibre connections on a JS22 blade in a BladeCenter H when running IBM i? A.) SFF (Small Form Factor) B.) StFF (Standard Form Factor) c.) CFFv (Combination Form Factor - vertical) D.) CFFh (Combination Form Factor - Horizontal) Answer: D, Well if you guess that the Blade Center H is a Horizontal oriented box then a horizontal card would be the logical choice and you would be right (but also wrong). Each of these cards will fit in the JS22 BCH but only the CFFh card is for Fibre and Ethernet. IBM will tell you so at the bottom of... http://www-01.ibm.com/common/ssi/cgi-bin/ssialias?infotype=AN&subtype=CA&htmlfid=897/ENUS108-075&appname=USN 32.) Which of the following is used to size the requirements for a CBU system? A.) iDoctor B.) Service Agent C.) Patrol Predict D.) Workload Estimator Answer: D, THis is what workload estimator does but if you are inclined - download the 1022 page 570 and 595 Redbook and look for "Sizing" you will find Workload Estimator nearby. 33.) Which of the following will impact the number of System x servers that can effectively attach to an iSCSI Host Bus Adapter? A.) The System i firmware level B.) The firmware level of the System x C.) The I/O workload of each System X Server D.) THe length of the cable connecting the server Answer: C, The actual number will depend on the amount of I/O that each blade or System x model is doing. But, if you don't believe me check out... http://www-03.ibm.com/systems/i/advantages/integratedserver/iscsi/index.html 34.) A Customer has worldwide operations. They currently have a Power 520 in the United States, an iSeries 810 in the UK and a Power 5+ 525 in Japan. They want to consolidate to one data center with one system but they must maintain local time and currency information for each location. Which of the following satisfies the requirement? A.) A Power 6 with three partitions B.) A power 6 with one partition and three cores activated c.) A Power 6 with two partitions since the UK and the US both speak english D.) A Power 6 with one partition using the new multicurrency and multi-timezone feature in V6R1 Answer: D, IBM globalization program, see... http://www-01.ibm.com/software/globalization/topics/icu/intro.jsp 35.) Which of the following configurations supports the EXP 12S? A.) Connectivity to the internal RAID controller in the one-core Power 520 B.) Connectivity to the FC #5782 RAID Controller for external Disk Drawers C.) Connectivity to the FC #5777 RAID Controller for external Disk Drawers D.) Connectivity to the internal RAID controller in the dual-core Power 520 Answer: B, The EXP 12S is a FC 5886 External Disk drawer. The Disk Drawer has to connect to the system and it uses a FC #5782 to accomplish this task. The 5886 and the 5782 are mention together at the following location... http://www-01.ibm.com/common/ssi/cgi-bin/ssialias?subtype=ca&infotype=an&appname=iSource&supplier=897&letternum=ENUS109-183&open&cm_mmc=4773-_-n-_-vrm_newsletter-_-10207_112515&cmibm_em=dm:0:1350918 but there is no mention of the 5777 so that would not make sense. A and D are out because this is an external RAID so we need to use the external RAID controller. 36.) A Customer with a V5R4 Power 5 system is upgrading to V6R1. Which of the following is the recommended order to upgrade user-created program objects? A.) Upgrade to V6R1, then run ANZOBJCVN with the convert option B.) Run ANZOBJCVN with the convert option, then upgrade to V6R1 C.) Upgrade to V6R1, run ANZOBJCVN, resolve issues, then run STROBJCNV D.) Run ANZOBJCVN, resolve issues, upgrade to V6R1, then run STROBJCNV command Answr: D, IBM recommends using the Analyze Object Conversion (ANZOBJCVN) tool to prepare for your conversion to i5/OS V6R1. ANZOBJCVN analyzes the objects on your i5/OS server and provides reports predicting how long conversion will take. The tool also notifies you of any program objects that won’t convert when you upgrade to V6R1 or migrate to a new system installed with V6R1 37.) Which of the following tape drives is supported by Power6? A.) 3580-H13 B.) 3580-L43 C.) 3570-C01 D.) 7208-342 Answer: B: IBM specifically indicates they are not supporting the 3580-H13 and the 3570-C01 models at the following... http://www-01.ibm.com/common/ssi/cgi-bin/ssialias?infotype=an&subtype=ca&htmlfid=897/ENUS107-448&appname=usn It says nothing about support for the 3580-L43 which requires V5R3 or later OS (very recent introduction) and the 7208-342 was introduced in the V4 timefame so it's support is long out of date IBM doesn't even mention it as an option. 38.) Which of the following is the tape hardware encryption mode supported for an IBM i environment? A.) BRMS - Managed Encryption (BME) B.) System-Managed Encryption (SME) C.) Library-Managed Encryption (LME) D.) Application-Managed Encryption (AM) Answer: C, Library managed dictates what is encrypted and what isn't BRMS is the philosphy but LME is the mode, don't beleive me see.... www-03.ibm.com/.../Tape_Encryption_and_BRMS_on_system_i.ppt 39.) After a system is designed in the System Planning Tool, the design is exported from SPT into which of the following tools to generate pricing and ordering information? A.) eConfig B.) eManufacture C.) System Pricer D.) System Builder Answer: A, You can export a system plan as a .cfr file and import it into the marketing configurator (eConfig) tool to use for ordering a system. See... http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphat/iphc6spt.htm 40.) Which of the following should be considered when using device parity protection with hot spare disk units? A.) Hot spare disk units can protect parity sets with smaller capacity disk units when using SAS IOA's B.) Hot spare disk units can protect parity sets with smaller capacity disk units when using SCSI IOA's C.) When creating a new RAID-6 parity set with hot spare disk units, a minimum of 6 disk units are required D.) When creating a new RAID-5 parity set with hot spare disk units, a minimum of 6 disk units are required Answer: A, Both of the disk units must be the same capacity for a Small Computer System Interface (SCSI) IOA, or the same or larger capacity for a Serial Attached SCSI (SAS) IOA http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/areaj/iphau_rzalydpphs.htm 41.) Which of the following is used to design SAN storage configurations? A.) Disk Magic B.) Workload Estimator C.) Performance Navigator D.) Operations Navigator Disk Performance Monitor Answer: A, The process for sizing the DS4000, DS6000, and DS8000 is done with Disk Magic. If you’re migrating an existing workload to VIOS and DS4000 or to DS6000 or DS8000 you can take the existing performance tool output and import it into Disk Magic. That can be used to establish a Base Model. Then you solve for the optimal Hardware configuration based on your growth, hardware deployment, types of drives, etc. The output is a nice collection of reports and graphs showing the expected performance based on your input. Disk system designs go to Disk Magic. 42.) When selecting the acoustic door option for an IBM rack, what must be considered prior to installation in the Computer room? A.) Anti-tip plates are required B.) Additional space is required C.) Rack mounted UPS will not be supported D.) 2U will be lost at the top and the bottom of the rack Answer: B, Acoustic doors are deeper than the standard doors and have sound deadening properties. This adds about 7.5 inches (19.05 cm) to the front and back for a total depth of 15 inches(38.1 cm) See... https://www-03.ibm.com/systems/x/hardware/options/cooling.html 43.)a CUSTOMER IS IMPLEMENTING A ds8000 san FOR THEIR pOWER SERVER. aLL DISK STORAGE IS EXTERNAL. tHE cUSTOMER HAS A SECOND ds8000 AND pOWER sERVER in a remote location 120 (200 KM) away. Which SAN feature is most practical for data replication between DS8000 SANS which are 120 miles (2oo KM) apart? A.) Flash Copy B.) Metro Mirror C.) Global Mirror D.) Cross-Site Morroring Answer: C, Separating data centers by longer distances helps to provide protection from regional outages. This asynchronous technique provides better performance at unlimited distances. With global mirror data copied to the backup site is current with the production site in a matter of seconds. Global mirror creates a disaster recovery solution that provides high performance and a cost effective approach to data replication across global distances, distances geater then 100 miles. 44.) A Customer with a Power 525 has 6 drives in the CEC and wants to migrate to a new Power 520. Which of the following is the easiest way to migrate this configuration? A.) Install all 6 drives from the 525 CEC into the Power 520 CEC B.) Connect both systems to the same HMC. USe the dedicated Service Tools (DTS) Migrate While Active option C.) Using the FC #5172 SAS Conversion cable , migrate all the SCSI drives, as an intact RAID array to a new machine D.) Using an HMC and an FC #5095 expansion unit, move thedrives from the 525 to the FC #5095 expansion unit. Then connect the FC #5095 expansion unit to the Power 520 and mark it as the load source location. Answer: A, C. - 5172 does not seem to be a conversion cable; D, a FC would be required to make an external disk array the load source (just seems like they would mention it in the answer); Not sure what a DTS migrate while active option is but it doesn't seem to be a native IBM feature. A just seems so easy and obvious that I believe it is correct. 45.) What is the minimum number of partitions that must be configured on a JS23 blade that runs IBM i? A.) 1 B.) 2 C.) 3 D.) 4 Answer: A, The POWER6™ Hypervisor treats the default configuration as one logical partition with one partition profile. Sounds liek default means minimum and I can't get much lower then one so that is what I am going with. 46.) Which of the following is a function of RAID-5 with Hot Spare? A.) One hot spare provides a redundant copy of the parity stripe. B.) One Hot Spare creates a virtual image of a single RAID Array C.) One Hot Spare can support multiple RAID arrays on the same controller D.) One Hot Spare can support all disk controllers in a single expansion unit Answer: C, Global hot-spare drives are supported. The drive that is designated as a hot spare should be as large as or larger than other drives in the system. Once you think of it as global hot spare the answer points to multiple RAID array support (or why would you did a larger drive as the hot spare). 47.) Which of the following can be used to help keep the BladeCenter S environment quiet and secure? A.) Redundant power and Security B.) Blade Center Office Enablement kit c.) Variable speed fans and security kit D.) Accoustical doors and biometric operator panel Answer: B.) THE BCOE kit combines accoustic comforts for the office while providing security for the system. Don't beleive me? read page one of the following... http://publib.boulder.ibm.com/infocenter/bladectr/documentation/topic/com.ibm.bladecenter.chassisop.oek.doc/mj1kf_office_enablement_kit_installation_guide_v1.pdf 48.) A Customer has a Power 520 with all drive, including the load source, installed in an external tower. Which feature can the Customer order to ensure the availability of the tower and system ASP? A.) Dual UPS B.) Dual line cords C.) FC #9406 secondary power supply D.) Intelligent Power Distribution Units (PDUs) Answer: B, Everything is so power related but the Dual Line Cord, when researched at http://www.stratus.ecacsupport.com/servicedocinternal/pdf/ha046.pdf has nothing to do with power and everything to do with connectivity from the tower to the CEC and making that connection redundant, thus ensuring availability. 49.) A Customer wants to implement DB2 Web Query with Named User Licensing. What must be done for each user? A.) For each user run CALL QWEBQRY76/WQADDLIC 'usrpf' B.) Run the WEBQRY ADM command and add the user profiles in the user names list C.) Add each user to the list displayed with the WRKLICINF PRDID(5733QU2) command D.) Change with the WRKUSRPRF command the WEBQRY parameter to *ENABLED in each user profile. Answer: A, Why because it is what you have to do, IF you dont believe me well check this out... http://bbs2.chinaunix.net/archiver/tid-1515038.html Nothing else comes close when you look for it. 50.) What is the Maximum number of 3.5 inch SAS drives that the internal RAID controller of a dual core power 520 can manage? A.) 6 B.) 18 C.) 12 D.) 20 Answer: A, THE 520 CEC can support six SAS disks. IF that is true and they all must be managed by a RAID controller then I would beleive that, at the most, six disks could be in the array. 51.) A customer has a requirement for Power VM to support four IBM i partitions and a Linux partition Which of the following is the minimum edition of Power VM that mees the Customer requirements? A.) Express B.) Standard C.) Enhanced D.) Enterprise Answer: B, This is the level where full micro partionoing is supported which will allow the system to surpass three partions. Express allows only three partitons. For more details see.... ftp://ftp.software.ibm.com/common/ssi/pm/sp/n/pod03015usen/POD03015USEN.PDF PowerVM Standard Edition is supported on POWER5 and POWER6processor based servers and blades and supports the features included inExpress Edition plus full micro-partitioning, HMC management, andMultiple Shared Processor Pool 52.) A Customer's auditor will no longer allow system console access anywhere except at the HMC itself. In what section of the HMC can remote 5250 console sessions be disabled? A.) Firewall Configuration B.) Remote Virtual Terminal C.) Remote Console Operations D.) Change User Interface Settings Answer: B, In the Remote Virtual terminal. See... http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/ipha1/hmcmanagementandservicemanagementtasks.htm 53.) An IBM iCustomer has several Windows based applications and requires 4 Blade servers to support them. The applications are disk intensive and performance is critical. IBM i will host the disks for the blades. Which of the following iSCSI solution provides the best performance? A.) 1 targer HBA and 1 switch model B.) 1 target HBA and 2 switch modules c.) 4 target HBAs and 4 switch modules D.) 2 target HBAs and 2 switch modules Answer: C, For each blade or System x model, storage access may be distributed over up to 4 IBM i iSCSI targets. Going with four target HBAs so everything else is irrelavant. 54.) Which of the following is a function of the Active Energy Manager when using the FC #7109 PDU+? A.) Energy consumption can be reduced for 12x I/O drawers, HSL I/O drawers and towers B.) Power saver mode can be enabled and disabled automatically during an IPL of the system c.) External devices that are not being used can be varied off automatically to save energy D.) Power saver mode can be enabled to reduce overall energy consumption without disrupting operations. Answer: A, The key is what does FC 7109 allow and that is the inclusion of towers in the Active Energy Manager process. B,C and D arr all things the Active Energy Manager does but when the PDU is brought into the picture you extend capabilities to external towers, and storgae devices. See... http://www.redbooks.ibm.com/redpapers/pdfs/redp4403.pdf 55.) What is the maximum number of non-virtualized partitions that can connect to the EXP24 disk storage unit? A.) 1 B.) 2 C.) 3 D.) 4 Answer: D, Configurable as either 4 groups of 6 drives or 2 groups of 12 drives with either single or dual connection any group of drives. IF each group of drives hosts a logical partition then 4. See... http://www-03.ibm.com/systems/storage/disk/exp24/index.html 56.) A Customer currently has a FC# 5094 expansion unit which they want to migrate to a dual core Power 520. They want to rack mount the Power 520 and add one additional I/O expansion drawer Which of the following addresses the customer requirements? A.) Add a 12 X loop to attach the FC #5094 and the FC # 5796 expansion drawer to the 520 B.) Add an HSL-2/RIO loop to attach the FC#5094, and add a FC#5790 expansion drawer to the 520 C.) Add an HSL-2/RIO loop to attach the FC#5094, and add a 12x loop to attach the FC# 5796 expansion drawer to the 520 D.) Add a 12X loop to the 520, and add the FC #2888 12X adapter to the FC #5796 expansion drawer to the 12X Loop Answer: B, First a dual core machine can only have one loop so C is wrong. THere is no adapter FC#2888 so D is wrong. and the FC 5094 is a HSL-2 connection system so it can't be used on a 12x connection so A is out. This leaves B and both Feature Codes support HSL-2 connections so B is right. 57.) A Customer is migrating from a 270 to a one-core Power 520 with V5R4M5 and has the following requirements: LTO-4 for back-ups on the new 520 LAN COnsole One Internal Modem Which of the following features provides the correct configuration? A.) One FC #5736 Tape IOA and one FC# 2893 2-line WAN IOA B.) One FC #5746 internal tape drive and one FC #9793 2-line WAN IOA C.) One FC #5775 Tape IOA and one FC #2893 IOPless 2-line WAN IOA D.) One FC #5746 internal tape and one FC #2893 IOPLess 2-line WAN IOA Answer: D, the FC #5746 is the LTO-4 tape drive and the 2893 is the IOPless modem (which is required for Power 6 hardware) and the 2893 contains a modem. See... http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphcd/fc2894.htm and the 5746 question was answered in 974 training materials. 58.) Which of the following will allow a Customer to display and monitor FC #7109 PDU+ energy usage data at various times of the day via Ethernet connection to a PC? A.) Management Central B.) Display Power Managemetn (DPM) C.) System Director Navigator for i5/0S D.) Systems Director Active Energy Manager Answer: D, The PDU+ can communicate its power monitor information using its Ethernet connection to a PC workstation running the IBM Active Energy Manager extension to the well-known IBM Systems Director, release level 5.20.2. See.... http://www.redbooks.ibm.com/redpapers/pdfs/redp4403.pdf 59.) Which of the following migrates from the Power 5+ system into the Power 6 system unit? A.) SCSI disk drives B.) FC #2844 IOP Card C.) FC #4746 Twinax Card D.) FC #5706 Dual Port Ethernet Card Answer D, The Power 6 CEC support SAS drives so SCSI drives are a no go- good bye to A., IOP cards don't work in Power 6 hardware so good-bye to B. The FC #4746 was a card in the year 2000 product line - good-bye C. So, D is left and it actually has Power 6 information available... http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphcd/pcibyfeature.htm 60.) What is the maximum number of virtual proccessors that can be configured for a partiton which has been allocated a single physical partion? A.) 2 B.) 4 C.) 9 D.) 10 Answer: D, The virtual processors have capacities ranging from 10 percent of a physical processor to the entire processor. See.... http://publib.boulder.ibm.com/infocenter/pseries/v5r3/index.jsp?topic=/com.ibm.aix.prftungd/doc/prftungd/micro_part.htm 61.) An iSeries 810 Customer has a FC#5094 PCI expansion tower with FC #4326 35 GB 15 K RPM disk drives. They would like to migrate to a rack mounted 520 solution, retaining as much existing hardware as possible. Which of these satisfies the rack mounting requirements? A.) Upgrade the existing FC # 5094 to a FC #5294 expansion unit B.) Order the RPQ to rack mount the existing FC #5094 in a new FC #0551 rack. C.) Replace the existing FC #5094 with new FC #5094 expansion unit to support the IOA and IOP cards along with the disk drives that were in the FC #5094. D.) Replace the exisitng FC #5094 with the new FC #5796 expansion units to support the IOA and IOP cards. Install new EXP24 expansion units to support the disk drives that were in the FC #5094. Answer: C, I don't know it's a guess but everything I could not find pointed more towards this direction then anything else. D isn't right and A and B dont migrate to a rack. 62.) Which of the following components will migrate to the FC #5796 expansion unit? A.) FC#2844 IOP, FC # 5736 tape adapter, FC #4746 Twinax adapter B.) FC#2757 RAID adapter, FC #5736 tape adapter, FC # 5706 dual port Ethernet Adapter C.) FC #5775 tape adapter, FC#5706 dual port EThernet adapter, FC #5776 RAID controller D.) FC #4327 15K RPM disk drives, FC #2849 EThernet adapter, FC #5990 RAID adapter with hauxiliary cache Answer: C, Best guess on all three components but IOP is not supported in the 5796, 2757 is an internal RAID controller and the 2849 is a graphics PCI card so what has that got to do with the expansion tower, this leaves C. 63.) A customer has a requirement for an IBM i environment and two Windows servers. What benefit does hosting these additional systems on the Power Systems server and connecting them with iSCSI provide? A.) Decreased power consumption B.) Lower licensing cost for Windows C.) Centralized back-up from the IBM ipartition D.) Improved performance for all database functions Answer: C, iSCSI points me this way, that is required to consolidate back-ups. B and D are easy to remove and A has some valideity in regards to IBM's go green intiative but why connect to something using iSCSI, keep it local to save energy (Power VM) so I say C. 64.) An IOP card can be used for which of the following? A.) To Support up to four IOA cards? B.) To Support IOP-less adapter cards C.) To support two fibre disk (IOA) adapters D.) It can be placed next to another IOP to improve the performance of a RAID adapter (IOA) Answer: A, I/O processor (IOP) adapters process instructions from the server and work with IOP controlled I/O adapters (IOAs) to control the I/O devices. An IOP card can support up to four IOA adapters. http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/areab/areabiop.htm 65.) A Customer is planning to connect an iSCSI attached System x to their 550. Which of the following must be done to support the configuration? A.) Install IBM Director Server on the 550 B.) Install IBM Director Console on the 550 C.) Install IBM director on the System x and 550 D.) Install iSCSI Extenders for IBM i (option 62) on the 550 Answer: A, If you look in the SYSTEm X configuration section there is nothing to install, configure yes but install...no. See... http://publib.boulder.ibm.com/infocenter/eserver/v1r2/index.jsp?topic=/diricinfo/fqm0_r_tbs_ibm_director_server.html 66.) A customer's nightly processing window must shrink from 4 hours to 2 hours. Which of the following methods will provide information needed to help address this requirement A.) Use iDoctor heap analysis to evaluate batch job memory usage B.) Turn on Collection Services. Evaluate system changes using this data C.) Set up a performance monitor through Management Central and evaluate the resulting performance collections D.) Run work with active Jobs (WRKACTJOB) with automatic refresh interval. Evaluate I/O performance during the nightly window Answer: B, Collection Services collects performance data continuously and automatically with minimal system overhead See... http://publib.boulder.ibm.com/infocenter/director/v6r1x/index.jsp?topic=/director_6.1/fqm0_main.html 67.) A Customer has a Power 5 model 525 in a DS8100 SAN environment and uses an HMC console. which of the following uses the least additional hardware when creating a new V6 R1 partition? A.) Virtual LAN; VIOS to SAN B.) LAN IOA; Fibre Channel disk IOA C.) Virtual LAN; Fibre Channel disk IOA D.) Virtual LAN; One Disk Controller; Two mirrored disk drives Answer: C, Not sure if it is C or A but VIOS is used to connect blade servers to SANS and there is no blade server in this situation. 68.) A Customer has a Power 570 system with a single CEC and nine FC #0595 expansion units. The Customer is interested in a proposal to upgrade to a Power6 570 system with new additional EXP 24 expansion drawers. Which of the following is the approriate loop configurations for this proposal? A.) Add a new 12X loop to support the new EXP 24 drawers B.) Use HSL-2/RIO attached drawers to support the new EXP24 drawers C.) Replace one HSL-2RIO loop with a 12X loop to support the new EXP24 drawers D.) Upgrade 3 of the FC #0595 drawers to a 12X and replace one HSL-2/RIO loop with a 12 X loop to support the new EXP 24 drawers Answer: D, An HSL-2/RIO loop can only support six drawers onm a Power 570 system and D is the only answer that makes the adjustment from 9 to 6 drawers and is valid with a 12X loop and an HSL-2/RIO loop. 69.) A Customer would like to attach both a SCSI-attached 3533 tape Library and a 7212-103 external DVD for support on multiple LPARS. Which of the following supports these devices at the lowest cost? A.) Configure one FC# 5761 one port media controller and daisy chain the SCSI devices B.) Configure one FC #5736 two port media controller and connect each SCSI device to its own port C.) Configure one FC # 5775 two port IOPless media controller and connect each SCSI device to it's own port D.) Configure one FC # 5736 two port media controller and connect the DVD for the tape library and one FC #5775 two port IOPless media controller for the DVD. Answer: B, Just feels right - cheap but effective. A doesn't seem to work and C and D are more expensive (will work) but more expensive. 70.) A customer has a one-core Power 520 with an extremely limited window for back-ups. Which of the following will provide the smallest back-up window? A.) Use Virutal tape B.) Use IBM i Managed compression C.) Use IBM iCluster SMB and a second system D.) Use Flashcopy and then save the second copy to tape. Answer: A, Allows uuse to save time by configuring multiple save jobs to execute at the same time. Once virtual back-ups are made then they can be moved to physical tape drive as course of normal operations. http://www.redbooks.ibm.com/redbooks/SG247164/wwhelp/wwhimpl/java/html/wwhelp.htm 71.) The 4GB Fibre Card, FC #5774, supports which of the following? A.) External disk only B.) LTO tape drives only C.) External disk and tape concurrently D.) External disk and tape non-concurrently Answer:C, A and B make no sense because this is a dual port card so it can do more then one thing and not "Only", D makes no sense because you can hook two things to it concurrently so the point would be to support it concurrently, C... http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphcd/fc5774.htm I menat "see...." :-) Come on it's three in the morning what did you expect 72.) HMC Version 7 is a valid release for which of the following Power Processors? A.) Power 6 only B.) Power 5+ and Power 6 C.) Power 4, Power5 and Power 6 D.) Power5, Power5+ and Power6 Answer: D, It is required for Power 6 but it works on Power 5. Nothing refered to about Power 4 so I would say no to Power4 support so D is the only viable answer, Refer to... http://www.ibm.com/developerworks/wikis/download/attachments/16253354/HMC+V7+and+System+i.pdf?version=1 73.) A Customer with an installed Power 5+ 525 running V5R4 and an HMC running at version 6, administers the system remotely. After upgrading the HMC to version 7 they are no longer able to login using WebSM. what must be done to remotely access the HMC? A.) Use a browser B.) Upgrade the WebSM client c.) Update the java on his PC D.) Open a virtual network connection (VNC) session Answer: A, Standard browser for remote GUI access to HMC V7.310 and above. See... http://www.ibm.com/developerworks/wikis/download/attachments/16253354/HMC+V7+and+System+i.pdf?version=1 74.) A customer is considering a partitioned Power server for system consolidation. After the system is configured which of the following is available in each partion without using the HMC? A.) Assigning a virtual LAN B.) LAN Console for each partiton C.) Powering on individual partions D.) Dynamic Resource movement from one partion to another Answer: B, everything else is done by the HMC included dynamic resource movement, which just means HMC process against an active partion or "on-the-fly administration. 75.) A customer has an 810 with a FC # 5074 expansion unit. the Customer is migrating to a Power 520 and wants to reuse the twinax Adapter, the Ethernet card and a SCSI tape controller. Which of the following meets the Customers requirments? A.) Convert the FC # 5074 from HSL 1 to 12X B.) Convert the FC #5074 from HSL 1 to HSL 2 C.) Replace the FC #5074 with a FC# 5790 expansion unit D.) Use a HSL to HSL 1 conversion cable to connect to the FC #5074 Answer: C, IBM just doesn't seem all that big on converting and adapters. They seem a lot more interested in replacing and since the 5074 has been around for a while it seems like it is time to get something nes - so C. 76.) Which of the following describes how to discover the IP addresses of the FSP without causing a system outage? A.) Engage switches on FSP to reset configuration B.) Run API QSYSFSPSTS and analyze the output to determine values C.) switch system to manual mode, use function 30 on the control panel D.) Sign in to the SST and use "display, alter, dump" in the appropriate data region Answer: C, I have no clue why this is right but it is, see.... 77.) A customer is installing a 550 with four FC#0595 expansion towers using redundant power on all units. How many PDU outlets are needed? A.) 5 B.) 6 C.) 8 D.) 10 Answer: D, 5 units (1 CEC and 4 expansion units) with redundant (2) Power supplies = 5 X2 = 10. 78.) What is required to provide individual, isolated TCP/IP connectivity from a production partition running on a Power 550 to each of three test partions on the same Power 550? A.) Three Virtual LANS B.) Four Virtual IP addresses C.) Four integrated Virtual Ethernet (IVE) adapters D.) Three Integrated virtual Ethernet adapters Answer: A, The result is that more than one VLAN can exist completely independent of each other on single physical segment. The advantage to this is that congestion on a LAN segment can be reduced and security can be improved by isolation of the traffic. See... http://publib.boulder.ibm.com/infocenter/zos/basics/index.jsp?topic=/com.ibm.zos.znetwork/znetwork_36.htm 79.) A Customer has a Power 5+ 550 with two cores activated and two IBM software licenses. they currently have one core activated for 5250 and use 3000 CPW of Interactive )5250) processing power. They plan to add a new interactive (5250) application that requires an additional 2000 CPW. Which of the following is required to support the additional workload? A.) 5250 Support Services for the 2nd Core B.) enterprise Enablement for 2nd Core C.) Power6 5250 enablement for 2nd Core D.) Enterprise Collaboration for 2nd Core Answer: C, see ...http://www.itjungle.com/tfh/tfh070708-story01.html 80.) Customer has two Power 520 systems and plans to connect a tape library with LTO-3 tape drives to each system. Which of the following reduces support and administrative efforts? A.) One TS3200 with the two systems connected to it. B.) Two TS3100s with one tape library connected to each system C.) One TS3100 with a Brocade SCSI switch connecting the two systems to tape library D.) One TS3100 with two systems connected to the tape library with a SCSI Y adapter Answer: A, The TS3200 supporrts multiple tape drives. Dedicate one to each system. Alright - disclaimer time. I have done my best to answer what I could. There are 89 questions on the test and I feel about 95 % comfortable with my response for 1 through 60. About 70% comfortable with 61 through 80 but the next 9 are best guess. There are 89 questions on the test and you need to get a 61%, 55 of 89. Believe me you can and this will help you but I am going to give you all the information but anything past here you can't hold me accountable to You'll still pass it's just a question of having everything right. I hope this helps you and if it does, alwyas remember Brain dumps are what you make of them. Contribute to the cause when you get a chance. Thank you, good luck and god bless... 81.) A Customer is running V5R3 on a Power 5 570 with several EXP 24 drawers and several FC #0595 drawers. They will be migrating to a Power 6 570 with V6R1. All EXP 24 drawers will migrate to the new system and the Fc#0595 disk will be migrated to new EXP 24 drawers Which of the following configurations meets the Customer requirements? A.) USe 12X connected expansion units for all EXP 24 drawers and....support for the existing IOP controlled IOAs B.) Use 12x connected expansion units for the new EXP 24 drawers and convert the existing EXP 24s from HSL to 12x attached disk expansion C.) Use 12x connected expansion units with new IOAs for the new EXP24 drawers. Migrate the IOAs and IOPs for the existing EXP24s to 12x attached expansion units. D.) Use 12x connected expansion units with new IOAs for the new EXP24 drawers. Migrate the IOAs for the existing EXP24s to 12X expansion units without the IOPs. Answer: A, best guess 82.) A Power Systems Customer would like to partition their Power 550 and upgrade to V6R1. The CPU requirements are; PArtition 1 - 2.0 cores minimum, 3.5 cores maximum Partition 2 - 0.5 core mnimum and 2.0 cores maximum Partition 3 - 1.0 core minimum, 2.0 core maximum How many IBM licenses are required? A.) 2 B.) 4 C.) 6 D.) 8 Answer: D, if you are on a 550 machine you have to activate 8 cores in order to handle the maximum load. You are more then seven so it has to be eight, one per core activated. 83.) A power 570 Customer has spare disk and memory capacity in the environment. They would like to setup a test environment for AIX. Which of the following describes the least disruptive method to provide disk and memory to the AIX partition? A.) remove unused disks from V6Ra and assign the drives to the AIX partition. B.) Install VIOS and assign all existing disks to the VIOS partiition and use VIOS to assign storage to the V6R1 and AIX partition. C.) Create a network storage space and network server description for the V6R1 partition. Configure the V6R1 partition as a virtual server and the AIX as a virtual SCSI client. D.) Create a network storage space and network storage server description and host the V6R1 partition. Configure the V6R1 partition as a virtual server. Create a VIOS partition as a SCSI client, to provide disk to the AIX partition. Answer: C, http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/iphat/iphbllinuxnwsd.htm 84.) A Customer would like to host an sshd daemon on one of their IBM ipartitions. What software products are required to provide this functionality? A.) 5761-TC1, TCP/IP connectivity for i5/OS, TCP/IP Unix command shell B.) 5761-TC1, TCP/IP connectivity for i5/OS and 5761-SS1 option of IBM i, Portable Application Solutions Environment C.) 5733-SC1, IBM portable utilities for i5/OS and 5761-SS1 option of IBM i, Portable Application Solutions Environment D.) 5761-SS1 option 33 for IBM i, Portable Application Solutions Environment and option 76 of IBM i, Unix Emulation enablers Answer: C, http://www-03.ibm.com/servers/enable/site/porting/tools/openssh.html 85.) A Customer running model 810 is experiencing application performance issues. They are considering migrating to a new Power Systems server The PM iSeries reports show all green lights and do not show an upward trend into yellow or red conditions. Which of the following will provide more accurate performance metrics? A.) Use the PM400 menu to change the collection interval, use the refresh option to resend the data and rerun the reports. B.) In System i Navigator, Collection services, set the PM server iSeries trend analysis to "trend current performance collection," and rerun the report C.) Use collection services to collect performance data. Change the default collection criteria to a short collection period and analyze those collections D.) In the PM400 menu, verify that the remote systems location includes the IBM PM iSeries system, use the refresh option to resend the data and rerun the reports. Answer: C, best guess 86.) An IT director would like a short overview of the migration process from an 810 at V5R4M5 to a JS23 blade. After upgrading to V6R1, which of the following describes IBM's recommended migration process? A.) The 810 is migrated using normal save and restore procedures and compatible tape drives on the model 810 B.) A full save of the 810 is performed to virtual tape. The virtual tape image is then copied to Vios and restored to the JS 23 blade. C.) The bladeCenter is installed with SLIC and base OS. User data is saved to virtual tape on the SAN and relaoded into the JS23 blade. D.) A full save is performed to virtual DVD. THe virtual DVD image is copied to VIOS on the JS23 blade. The V6R1 partition is IPLEd from the DVD image and the environment is loaded int othe partition. Answer: B, best guess 87. A JS23 blade is being added to an existing bladeCenter H (BCH). which of the following must be considered in the design? A.) the SAS tape interface feature is required for IBM i B.) IBM i disk mirroring must be used for disk protection C.) The JS23 blade expansion features must be compatible with the other blades and BCH I/O bays D.) VIOS provides a virtualized intervace which permits IBM i to use the same drives supported by IBM on i stand alone systems. Answer C, It just feels right - kinda of like I imagine how Halle Berry would feel through silk sheets. 88.) Customer has four logical partitions on a Power 570 running IBM i V5R4M5. The Customer wants to implement a back-up strategy that is flexible and requires minimal user intervention. Which of the following satisfies these requirements at a low cost A.) A shared FC #2844 IOP and FC #5736 SCSI card with one dedicated SCSI attached TS3100 tape library B.) A FC #2844 IOP and FC#5736 SCSI card in each partition having a dedicated SCSI attached TS3100 tape library C.) A FC #2844 IOP and FC#5761 Fibre card in each partition connected to a fibre switch with one fibre attached TS3100 Tape Library D.) A FC #2844 IOP and FC#5761 Fibre card in each partition with each partition having its own dedicated fibre attached TS3100 Tape Library Answer: C, best guess 89.) A Customer is migrating from a model 820 with six 17GB 10 K RPM drives running V5R3 to a Power 520 running V6R1. Which of the following is the recommended upgrade sequence of tasks to accomplish this migration? A.) Order the 520 with no preloaded discs in the CEC Upgrade the model 820 to V5R4 Move the disks drives from the 820 to the 520 CEC B.) Order the 520 with FC #5000 (complete I5/OS V6R1 preloaded) Do a complete system save on the model 820 Do a system restore with the update option on the 520 C.) Order the 520 with FC #0205 (SLIC and Base OS Loaded) Upgrade the 820 tosystem to V5R4 Do a complete system save on the model 820 Follow the steps in the backup and recovery guide for manual migration D.) Order the 520 with no preloaded and 6 disks in the CEC Upgrade the model 820 to V5R4 Do a complete system save on the model 820 Follow the steps in the Back-up Recocery guide for an automatic restore on the 520 Answer: D, hell I don't know - it sounds good to me. |
|||||
![]() |
Power Systems Technical Support for i | 0.00 | Jul 30,09 | ||
| I need more information about this certification | |||||
![]() |
IBM iseries test 974 | 0.00 | May 07,09 | ||
| IBM 974 test | |||||
![]() |
IBM 974 test | 0.00 | May 07,09 | ||
| IBM test 974 | |||||
| Displaying Rows 1 - 4 of 4 | Pages: 1 |
| Related IBM Braindumps Exams |
| Certified Specialist braindumps (IBM Certified Specialist): 000-386, 000-387, 000-253, 000-839, 000-223, 000-079, 000-190, 000-535, 000-917, 000-070, 000-266, 000-740, 000-743, 000-222, 000-252, 000-671, 000-228, 000-856, 000-512, 000-742, 000-747, 000-746, 000-745, 000-071, 000-074, 000-229, 000-239, 000-268, 000-382, 000-385, 000-388, 000-389, 000-424, 000-633, 000-634, 000-635, 000-636, 000-637, 000-638, 000-749, 000-641, 000-642, 000-645, 000-741, 000-751, 000-787, 000-816, 000-855, 000-857, 000-858, 000-866, 000-884, 000-351, 000-798, 000-357, 000-076, 000-748, 000-639, 000-204, 000-973, 000-331, 000-208, 000-863, 000-864, 000-330, 000-960, 000-923, 000-425, 000-906, 000-961, 000-665, 000-206, 000-111, 000-207 |
| Solutions Expert braindumps (IBM Certified Solutions Expert): 000-444, 000-512, 000-514, 000-640, 000-710, 000-711, 000-713, 000-714, 000-910, 000-915, 000-973, 000-330, 000-961, 000-061 |
| Cert Yourself - Free Practice Exams, Free Study Guides For MCSE, CCNA, A+, MCSD, N+ and much much more |
| Testking - The acknowledged leader in Certification Preparation |
| Real Exams - We have the Questions you will see in your Exams |
| Exact Questions - Register for free and Take FREE IT Courses! Click Here! |
| Exact Exams - Quality Exam Preparation - Available NOW! |



Title
Date


